Skip to content
Subfloor ventilation
Rising damp

Subfloor Ventilation St George

Dry out the space under the floor so the timber, the walls and the rooms above stop staying damp.

Get a free quote

Takes a minute. A local damp specialist will call you back.

No obligation. Your details only go to one local damp specialist.

Subfloor ventilation is one of the most useful damp repairs in St George, because so many houses here sit off the ground on piers. Federation and inter-war bungalows in Bexley, Kogarah and Hurstville, post-war fibro and weatherboard cottages across Penshurst, Mortdale, Peakhurst and Beverly Hills, and plenty of brick homes all have timber floors over a crawl space. When that space can’t breathe, damp builds up underneath.

Signs of a damp subfloor

Inside, you might notice a musty smell, strongest in winter and in the rooms closest to the ground; floorboards that cup, squeak more than they used to or feel soft; mould on the backs of wardrobes and furniture against outside walls; and damp or flaking paint along the bottom of walls.

Under the house, the signs are damp or dark soil, white or grey mould on the timber, rusted fixings and a heavy, earthy smell. We measure moisture in the bearers and joists to see whether the timber is at risk.

Why St George subfloors get damp

Lost vents. Over the years, vents get buried by garden beds, covered by decks and pergolas, or closed off when a back extension is added on a slab. In many houses one side of the subfloor ends up with no airflow at all.

Water getting underneath. Downpipes that empty beside the house, garden beds sloping toward the walls and leaking pipes put water under the floor. On blocks falling toward the Georges River, rain runs under the house from the high side.

Low, wet ground. Near the Cooks River and Botany Bay, the soil itself stays damp for long periods.

Low clearance. Some cottages sit very close to the ground, with little room for air to move.

How we fix it

Water first. We connect downpipes to drainage, lower soil that’s built up against the base, and flag any leaking plumbing. On sloping blocks a drain on the high side may be needed.

Then airflow. Blocked vents are cleared, debris and stored material under the house is moved so air can pass, and new vents are added so air can enter one side and leave the other. On brick base walls, we add air bricks. On fibro houses, we work with existing openings or the brick piers and base walls rather than cutting into old fibro sheeting.

Where natural airflow isn’t enough, we install quiet inline fans on a timer or humidity controller.

Fibro houses and asbestos

Fibro sheeting made before about 1990 may contain asbestos. We don’t drill, cut or sand old fibro. If any old sheeting needs to come off as part of the job, it has to be removed by a licensed asbestos removalist first. Our guide on damp in fibro cottages explains more.

Walls and floor together

A damp subfloor often comes with damp in brick base walls or the internal walls above. When it does, we combine airflow work with an injected damp course or membrane and damp plaster repairs inside, under one written quote.

For the full process, see rising damp treatment, or check the signs of rising damp to see what you’re dealing with.

Updated

The price depends on the size and height of the subfloor, access, the number of vents to clear or add and whether fans are needed. We get under the house before quoting.

What good subfloor ventilation looks like

Close-up of subfloor ventilation on a home in the St George area
What subfloor ventilation looks like up close on a typical St George area home.
Signs that subfloor ventilation needs attention
Typical signs that it needs attention.

Subfloor Ventilation in St George: step by step

  1. Go underCrawl in and measure the joists and bearers, look at the soil, the vents and any plumbing.
  2. Cut off the waterLeaks, downpipes discharging under the house and garden runoff are dealt with first.
  3. Open up the ventsBlocked vents are cleared and new ones added so air can cross the subfloor.
  4. Fans where neededQuiet inline fans move air along a set path where natural airflow falls short.

Subfloor Ventilation questions in St George

Something else on your mind? Call and ask.

My fibro cottage smells musty. Is that the subfloor?

Often, yes. Fibro and weatherboard cottages on piers rely on airflow under the floor. If the vents are blocked or the ground is wet, damp air rises through the floorboards.

Is it safe to work under a fibro house?

Fibro made before about 1990 may contain asbestos. We don't cut or drill old fibro; new vents go into brick base walls or existing openings. If any fibro needs removing, it must be done by a licensed asbestos removalist.

Do fans cost much to run?

Inline subfloor fans use little power, and running them on a timer or humidity controller keeps the cost down further.

Damp walls in St George?

📞 Call now Free quote